ENGLISHHOMECONTACT USSITEMAP

제품정보
Kyongshin PRODUCT

Zymo Research

Bertin

Saphymo (Bertin)

Berthold

Serumwerk

Biocomp

Capitalbio

Arrayjet

PolyAn

Hudson Robotics

ABER instrument

Arthus Biosystems

BioChain

Povair

BIOREAGENT(Bertin)

BIOREAGENT(Bertin)
▪ HOME>제품정보>BIOREAGENT(Bertin)
Angiotensin II inhibition cocktail
The Angiotensin II (AII) Inhibition Cocktail has been developped by Bertin Bioreagent in order to fix physiological concentration of Angiotensin II in biological samples namely blood. Indeed, it has been observed that sample preparation is highly recom...
서한형 대리
(010-8832-6303)

제품소개

<10ml>

Territorial Availability: Available worldwide directly through Bertin or your local distributor
Correlated keywords:
  • sample preparation
  • Angiotensin II
  • Angiotensin 2
  • Angiotensin
  • protease inhibitor
  • cardiovascular
Product Overview:
The Angiotensin II (AII) Inhibition Cocktail has been developped by Bertin Bioreagent in order to fix physiological concentration of Angiotensin II in biological samples namely blood. Indeed, it has been observed that sample preparation is highly recommanded when dosing Angiotensin II for preventing the formation or degration of AII in vitro.
Mix these solutions vial A and vial B to obtain the inhibitor cocktail ready to use. This solution has to be diluted 1:33 directly into the blood sample (i.e. for 1 mL of sample, add 30 μL of inhibition cocktail). The total volume is for approximately one sample of 10 mL of blood. After adding the inhibition cocktail, mix the tube and centrifuge at 3000g for 15 minutes at +4°C.
Important notes: Plasma has to be prepared less than 30 minutes after collecting blood. Once mixed, the inhibition cocktail should be used immediately.
Sizefor 10 ml of blood
Shippingdry ice
Application(s)

Prevent Angiontensin II formation and degradation

Sample volume10 mL
FormulationMix content of vial B into vial A (maximum volume of vial A is 10 mL) to obtain the ready-to-use 33x inhibition cocktail solution. Flocculation may appear.
Custom Code3822000000
UNSPSC code12352100


<50ml> 

Territorial Availability: Available worldwide directly through Bertin or your local distributor
Correlated keywords:
  • sample preparation
  • Angiotensin II
  • Angiotensin 2
  • Angiotensin
  • protease inhibitor
  • cardiovascular
Product Overview:
The angiotensin II (AII) Inhibition Cocktail has been developped by Bertin Bioreagent in order to fix physiological concentration of Angiotensin II in biological samples namely blood. Indeed, it has been observed that sample preparation is highly recommanded when dosing Angiotensin II for preventing the formation or degration of AII in vitro.
Mix these solutions vial A and vial B to obtain the inhibitor cocktail ready to use. This solution has to be diluted 1:33 directly into the blood sample (i.e. for 1 mL of sample, add 30 μL of inhibition cocktail). The total volume is for approximately one sample of 50 mL of blood. After adding the inhibition cocktail, mix the tube and centrifuge at 3000g for 15 minutes at +4°C.
Important notes: Plasma has to be prepared less than 30 minutes after collecting blood. Once mixed, the inhibition cocktail should be used immediately.
Sizefor 50 ml of blood
Shippingdry ice
Application(s)

Prevent Angiontensin II formation and degradation

Sample volume50 mL
FormulationMix content of vial B into vial A (maximum volume of vial A is 10 mL) to obtain the ready-to-use 33x inhibition cocktail solution. Flocculation may appear.
Custom Code3822000000
UNSPSC code12352100


<200ml> 

Territorial Availability: Available worldwide directly through Bertin or your local distributor
Correlated keywords:
  • sample preparation
  • Angiotensin II
  • Angiotensin 2
  • Angiotensin
  • protease inhibitor
  • cardiovascular
Product Overview:
The Angiotensin II (AII) Inhibition Cocktail has been developped by Bertin Bioreagent in order to fix physiological concentration of Angiotensin II in biological samples namely blood. Indeed, it has been observed that sample preparation is highly recommanded when dosing Angiotensin II for preventing the formation or degration of AII in vitro.
Mix these solutions vial A and vial B to obtain the inhibitor cocktail ready to use. This solution has to be diluted 1:33 directly into the blood sample (i.e. for 1 mL of sample, add 30 μL of inhibition cocktail). The total volume is for approximately one sample of 200 mL of blood. After adding the inhibition cocktail, mix the tube and centrifuge at 3000g for 15 minutes at +4°C.
Important notes: Plasma has to be prepared less than 30 minutes after collecting blood. Once mixed, the inhibition cocktail should be used immediately.
Sizefor 200 ml of blood
Shippingdry ice
Application(s)

Prevent Angiontensin II formation and degradation

Sample volume200 mL
FormulationMix content of vial B into vial A (maximum volume of vial A is 10 mL) to obtain the ready-to-use 33x inhibition cocktail solution. Flocculation may appear.
Custom Code3822000000
UNSPSC code12352100




주문정보

CAT.No 품명 규격 비고
D05006 Angiotensin II inhibition cocktail for 10 ml of blood Sample Preparation
D05006 Angiotensin II inhibition cocktail for 50 ml of blood Sample Preparation
D05006 Angiotensin II inhibition cocktail for 200 ml of blood Sample Preparation